AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Farmall A Underside

Postby AgTires4295 » Sat Oct 05, 2013 4:36 pm

I imagine this isnt normal. It appears as though everything is exposed! Am I wrong? Pictured is the shaft into the gear box. Im more concerned about the gear box having a gaping hole.

Image

Additionally, I'm having one heck of a time trying to get this A to crank over with the hand crank. Ive replaced the oil, spark plugs, spark plug wires, have a decent spark... Wondering what else is up? Ive determined that the starter is fried since I've tried over and over again (troubleshooting with a voltmeter).
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub

SPONSOR AD

Sponsor



Sponsor
 

User avatar
Super A
10+ Years
10+ Years
Posts: 5229
Joined: Mon Jan 26, 2004 10:53 am
Zip Code: 28521
Tractors Owned: Collector of Super As, Corn Pickers, and a buncha other junk. Even a Cub now and then...
Circle of Safety: Y
Location: NC, Jacksonville area

Re: Farmall A Underside

Postby Super A » Sat Oct 05, 2013 5:04 pm

The hole is in the torque tube aka clutch housing. The big one provides access for adjusting the clutch linkage. Other one I am not sure of the purpose but both are supposed to be that way.

Al
White Demo Super A Restoration Updates

Let us pray for farmers and all who prepare the soil for planting, that the seeds they sow may lead to a bountiful harvest.
Celebrating 75 years of the Super A: 1947-2022

User avatar
AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Re: Farmall A Underside

Postby AgTires4295 » Sat Oct 05, 2013 6:52 pm

As long as theyre supposed to be that way.
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub

User avatar
havoc1482
10+ Years
10+ Years
Posts: 987
Joined: Fri Sep 20, 2013 11:17 am
Zip Code: 01085
eBay ID: havoc1482
Tractors Owned: _______ 1948 Farmall Super A
Circle of Safety: Y
Twitter ID: @havoc1482
Location: Westfield, MA
Contact:

Re: Farmall A Underside

Postby havoc1482 » Sun Oct 06, 2013 10:59 am

I thought the same thing, they are supposed to be exposed. Now, generally what I do with the hand-crank is leave the button off, then turn the engine once or twice to pull some fuel in and charge the magneto, then flip the button and crank it, it typically starts right up.

So you're getting a spark when the engine turns? If that's the case then it must be a fuel delivery issue.
Mike
Image

I bleed Black & Gold

IH Collectors Club New England (Chapter 18)

Western Mass. (The 413)

User avatar
AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Re: Farmall A Underside

Postby AgTires4295 » Sun Oct 06, 2013 11:26 am

Reference the exposed comment: Great. I was getting worried since I'm seeing a lot of abuse and cut-corners on this tractor. Im really unsure if this thing is 6 or 12 volts. The starter looks original (Delco Remy) and that'd mean 6 volts but the generator (which also looks original but forget the name) clearly states 12 volts. Will have to post photos later. It has a voltage regulator under the fuel tank which looks well-done but I doubt is stock. Getting a little discouraged since I've dropped about 10 hours into it so far and havent gotten anywhere.

I was thinking that it cant be a fuel delivery problem since I'm bypassing that by giving it a shot of ether into the carb. I shot ether into the cylinders too while changing the spark plugs.
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub

User avatar
havoc1482
10+ Years
10+ Years
Posts: 987
Joined: Fri Sep 20, 2013 11:17 am
Zip Code: 01085
eBay ID: havoc1482
Tractors Owned: _______ 1948 Farmall Super A
Circle of Safety: Y
Twitter ID: @havoc1482
Location: Westfield, MA
Contact:

Re: Farmall A Underside

Postby havoc1482 » Sun Oct 06, 2013 12:01 pm

I would see if you can just make everything 6 volt or 12 volt to eliminate any possible incompatibilities. If you are unsure about what the status is with the ignition and electrical components, chances are that is where the problem lies.
Mike
Image

I bleed Black & Gold

IH Collectors Club New England (Chapter 18)

Western Mass. (The 413)

Eugene
Team Cub Mentor
Team Cub Mentor
Posts: 20344
Joined: Fri Jul 02, 2004 9:52 pm
Zip Code: 65051
Circle of Safety: Y
Location: Mo. Linn

Re: Farmall A Underside

Postby Eugene » Sun Oct 06, 2013 12:34 pm

Since the generator states 12 volts - 12 volt electrical system. Starter, either 6 or 12 volts, not a problem, either will work with a 12 volt system.

Your battery voltage is?

Delco Remy made 6 and 12 volt starters.

Conducted compression tests?
I have an excuse. CRS.

User avatar
AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Re: Farmall A Underside

Postby AgTires4295 » Sun Oct 06, 2013 1:20 pm

Im definitely looking for compatibility and would like to make it a 12 volt if I can (my Cub is 6v which makes it a little bit of a inconvenience).

Eugene wrote:Since the generator states 12 volts - 12 volt electrical system. Starter, either 6 or 12 volts, not a problem, either will work with a 12 volt system.

Your battery voltage is?

Delco Remy made 6 and 12 volt starters.

Conducted compression tests?


I tested the starter initially at 6v since I knew from looking on the forum that the stock form was also 6v. When I couldnt make that work, I figured it couldnt hurt to bump it with a 12v battery. Both 12v and 6v and the same result: nothing. Just a spark (bypassed the starter and went straight from the batteries with jumper cables). The whole reverse polarity thing has me scratching my head. On the printout I found, it states that its a positive ground. To me, this seems like a sin. Maybe somebody has something to add on that. Im on my way over to the barn now so I'll be sure to post up some photos.

I thought a 6v starter would blow up with 12v of cranking (hence why I bumped it just to see if it would come alive). Wondering what the next step is there.

I havent done a compression test but did pour a drip of Seafoam in each cylinder last week and slowly cranked it over by hand a few times just to get some sort of lubricant in there while it sat through the work week. In turning the crank with the plugs in vs open cylinders, there is good resistance so even though I dont know specifically what the numbers are yet, I'm fairly sure it has good enough compression to start.

Stay tuned.
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub

Eugene
Team Cub Mentor
Team Cub Mentor
Posts: 20344
Joined: Fri Jul 02, 2004 9:52 pm
Zip Code: 65051
Circle of Safety: Y
Location: Mo. Linn

Re: Farmall A Underside

Postby Eugene » Sun Oct 06, 2013 1:34 pm

AgTires4295 wrote:I thought a 6v starter would blow up with 12v of cranking (hence why I bumped it just to see if it would come alive).
Here is a previous post on 6 volt starters operating on a 12 volt electrical system.
Eugene wrote:
RustyKnuckles wrote:What happens if you run the 6v starter on 12v? Obviously shorter lifespan? Smoke and fire?
You will notice that the starter cranks over the engine faster. Other than that - nothing.

I have 3 tractors that were originally 6 volt. Owned some of these tractors for 15 or more years. Only had to repair one starter on a 60 plus year old tractor.

Also had one alternator fail in that time period. Alternator was on the tractor when I purchased it.
I have an excuse. CRS.

User avatar
AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Re: Farmall A Underside

Postby AgTires4295 » Sun Oct 06, 2013 2:08 pm

Great! Glad to have read that! Posting up photos now. Having issues with Photobucket.
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub

User avatar
AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Re: Farmall A Underside

Postby AgTires4295 » Sun Oct 06, 2013 2:28 pm

Starter (I just moved the band clamp over before the photo): Image

Coil/distributer with new spark plugs and wires: Image

Generator (matching brand to starter...original?): Image
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub

Eugene
Team Cub Mentor
Team Cub Mentor
Posts: 20344
Joined: Fri Jul 02, 2004 9:52 pm
Zip Code: 65051
Circle of Safety: Y
Location: Mo. Linn

Re: Farmall A Underside

Postby Eugene » Mon Oct 07, 2013 8:56 am

Is that beat up bolt and nut on the top of the starter the battery cable connection?

All electrical connections, including grounds, need to be cleaned up. The starter will require 150 or more amps to function. Starter and generator, rebuild yourself or take to rebuilder.

First thing I do after tractor purchase is to pressure spray, clean up, the entire tractor.

I would remove the valve cover. Check for bent push rods and slowly crank engine over by hand to see if all valves were functioning. Valves OK, conduct the compression test. Hand cranking the engine, readings will be quite a bit lower than cranking engine with starter. This will provide some indication of engine's ability to run.
I have an excuse. CRS.

User avatar
SONNY
10+ Years
10+ Years
Posts: 4087
Joined: Thu Nov 09, 2006 11:26 pm
Zip Code: 61722

Re: Farmall A Underside

Postby SONNY » Wed Oct 09, 2013 8:15 pm

I would bet that your starter is in bad shape inside!---If you are up to it,---take the starter apart and check all the connections,--brushes,--armature ,etc and clean up , replace if needed,---bearings could be quite worn too! thanks; sonny

User avatar
AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Re: Farmall A Underside

Postby AgTires4295 » Thu Oct 10, 2013 1:12 am

Eugene wrote:Is that beat up bolt and nut on the top of the starter the battery cable connection?

Ha yes if you wanna call it a bolt. It's basically a stripped out gob of copper now. The previous owner (no clue why) stripped it so badly that he drilled a screw in the center, connecting the hot wire.

All electrical connections, including grounds, need to be cleaned up. The starter will require 150 or more amps to function. Starter and generator, rebuild yourself or take to rebuilder.
Yeah I'll be breaking down the starter this weekend. Is it possible that from what you can see, the generator is original? I'm really thrown by the 12v stamp on it but it looks legitimately original to me.

First thing I do after tractor purchase is to pressure spray, clean up, the entire tractor.
Are there any spots more sensitive to water (other than the coil area obviously) than others?

I would remove the valve cover. Check for bent push rods and slowly crank engine over by hand to see if all valves were functioning. Valves OK, conduct the compression test. Hand cranking the engine, readings will be quite a bit lower than cranking engine with starter. This will provide some indication of engine's ability to run.

Roger.
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub

User avatar
AgTires4295
10+ Years
10+ Years
Posts: 197
Joined: Fri Dec 30, 2011 7:36 pm
Zip Code: 20646
Tractors Owned: 1940 Farmall A
1947 Farmall H
1951 Farmall Cub
1970 Cub Cadet 127
1970 Simplicity Broadmoor 728 (x2)
1984 Cub Cadet 782
1964 Simplicity Landlord
2014 Simplicity Broadmoor 23/50
Location: La Plata, MD

Re: Farmall A Underside

Postby AgTires4295 » Thu Oct 10, 2013 1:16 am

SONNY wrote:I would bet that your starter is in bad shape inside!---If you are up to it,---take the starter apart and check all the connections,--brushes,--armature ,etc and clean up , replace if needed,---bearings could be quite worn too! thanks; sonny


Yeah, I'll be breaking down the starter and doing just that. From what I can tell, the bendix is near frozen and the shaft doesnt move at all. Hoping to get some cranking power ASAP. My right shoulder will thank me.
Image
1940 Farmall A
1947 Farmall H
1951 Farmall Cub