generator issues
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
-
- 10+ Years
- Posts: 34
- Joined: Mon Jul 23, 2012 7:19 am
- Zip Code: 45862
generator issues
Good afternoon. This problem must be explained somewhere but I can't find it. I have a 1953 farmall cub with a 6 volt positive ground generator and voltage regulator. It has been charging ok until last week. I have the cover off the regulator and when starting the tractor, the relay points jump for a couple seconds then when they close, the ammeter pegs out on discharge. I am afraid to run John's test as I don't want to mess anything up. Does anyone have any idea what's going on? Thanks, Bill
-
- 10+ Years
- Posts: 1087
- Joined: Sun Apr 18, 2010 6:22 am
- Zip Code: 21742
- Tractors Owned: 1955 F Cub (2)
1952 F Cub
1948 F Cub
2155 JD
216 JD - Circle of Safety: Y
- Location: Hagerstown MD
Re: generator issues
Let's start with the simple things first. Repolarize your generator. Here is how it is done.
http://farmallcub.com/phpBB2/viewtopic.php?f=11&t=56748
http://farmallcub.com/phpBB2/viewtopic.php?f=11&t=56748
-
- 10+ Years
- Posts: 34
- Joined: Mon Jul 23, 2012 7:19 am
- Zip Code: 45862
Re: generator issues
I polorized it twice, still the same. Would a bad voltage regulater do this?
-
- 10+ Years
- Posts: 1087
- Joined: Sun Apr 18, 2010 6:22 am
- Zip Code: 21742
- Tractors Owned: 1955 F Cub (2)
1952 F Cub
1948 F Cub
2155 JD
216 JD - Circle of Safety: Y
- Location: Hagerstown MD
Re: generator issues
There are lots to things that could be causing the problem. What I try to do is first ask myself if anything was done to the tractor since it was working correctly. Sometimes changes to wiring, battery hookup, etc., may point to the problem. If nothing is apparent, then wear and tear may be the cause. The next thing I would do is, with the ignition turned off, pull a strip of coarse paper a few times between each point as you manually hold the points down lightly against the paper. A piece of paper from a shopping bag will work. Sometimes the point surfaces can build up debris on the surface that prevents solid contact.
-
- 10+ Years
- Posts: 34
- Joined: Mon Jul 23, 2012 7:19 am
- Zip Code: 45862
Re: generator issues
I filed the points and blew them off. I took the wires off the generator and show a continuity between the A and F posts. I wouldn't think there should be, shorted on the inside? I was mowing when it went haywire.
-
- 10+ Years
- Posts: 1087
- Joined: Sun Apr 18, 2010 6:22 am
- Zip Code: 21742
- Tractors Owned: 1955 F Cub (2)
1952 F Cub
1948 F Cub
2155 JD
216 JD - Circle of Safety: Y
- Location: Hagerstown MD
Re: generator issues
If the the tractor starts OK, we can assume your battery cables are not corroded. When facing the regulator, the cutout relay will be on the left side. This cutout has to close before you will see a positive charge on your ammeter. If the cutout relay does not close after the tractor starts, have someone lightly hold the contacts together while someone observes the ammeter. If you get a positive charge on the ammeter, your generator is good. If the points remain closed after you manually close them, the points are either slightly too far apart or your generator is not putting out enoungh current to energize the magnet in the relay to initiate the closing of the cutout points.
-
- 10+ Years
- Posts: 5215
- Joined: Tue Jan 12, 2010 2:08 pm
- Zip Code: 12514
- Circle of Safety: Y
Re: generator issues
try this
- Attachments
-
- 08-Regulatortroubleshootingchartrev.gif (56.29 KiB) Viewed 448 times
-
- 10+ Years
- Posts: 34
- Joined: Mon Jul 23, 2012 7:19 am
- Zip Code: 45862
Re: generator issues
I'm afraid to try the trouble-shooting chart, as soon as the relay points close, the ammeter needle pegs to discharge. I don't want to burn something out . when facing the voltage regulater on the right side of the tractor, my relay points are on the right side of the regulater. I have the 2 point reg., 3 fixed brush gen. Thanks, Bill
-
- 10+ Years
- Posts: 1087
- Joined: Sun Apr 18, 2010 6:22 am
- Zip Code: 21742
- Tractors Owned: 1955 F Cub (2)
1952 F Cub
1948 F Cub
2155 JD
216 JD - Circle of Safety: Y
- Location: Hagerstown MD
Re: generator issues
We need to make sure we are both referring to the cutout relay. The cutout relay is connected to BAT terminal on the regulator. Here is an an instruction sheet from Delco Remy. It describes both the two and three relay regulators.
A negative reading on the ammeter means current is flowing from your battery to the regulator and/ or generator. If the ammeter needle is pegged to minus, it suggests a short in one of the two units. When you turn the ignition on without the tractor running, what is the reading on the ammeter?
http://www.ruiter.ca/mc/info/PDFs/1R-116.pdf
A negative reading on the ammeter means current is flowing from your battery to the regulator and/ or generator. If the ammeter needle is pegged to minus, it suggests a short in one of the two units. When you turn the ignition on without the tractor running, what is the reading on the ammeter?
http://www.ruiter.ca/mc/info/PDFs/1R-116.pdf
-
- 10+ Years
- Posts: 34
- Joined: Mon Jul 23, 2012 7:19 am
- Zip Code: 45862
Re: generator issues
The needle is just left of center about 1 mark.
-
- 10+ Years
- Posts: 1087
- Joined: Sun Apr 18, 2010 6:22 am
- Zip Code: 21742
- Tractors Owned: 1955 F Cub (2)
1952 F Cub
1948 F Cub
2155 JD
216 JD - Circle of Safety: Y
- Location: Hagerstown MD
Re: generator issues
The ammeter will normally indicate a slight discharge when you turn on the ignition with the tractor not running. This discharge is through the ignition points and is a normal occurance. It appears there is nothing unusual until the tractor starts and the regulator points close. It appears to me that your regulator is defective. I say this because the relay points in the regulator would not close unless your generator is putting out current. This seems to discount the generator as the culprit. I am not sure why you are getting what appears to be a dead short when the regulator points close unless there is a short in the regulator. Instead of the a normal situation where the current from the generator would be directed to your battery with a positive indication on the ammeter, you have the reverse occurring occuring - battery to regulator - as soon as the points close.
-
- 10+ Years
- Posts: 34
- Joined: Mon Jul 23, 2012 7:19 am
- Zip Code: 45862
Re: generator issues
Thanks. I will get a new regulator and try it. I ran the motor test on the generator, neg. to A. pos. to a gen ground, F to ground. The gen ran, when I took the F ground off, it quit. I read where the gen should have sped up. Is this always the case? Thanks for all the help. My cub is all original, I use it to plow snow in the winter and mow the woods in the summer. Bill
-
- 10+ Years
- Posts: 1087
- Joined: Sun Apr 18, 2010 6:22 am
- Zip Code: 21742
- Tractors Owned: 1955 F Cub (2)
1952 F Cub
1948 F Cub
2155 JD
216 JD - Circle of Safety: Y
- Location: Hagerstown MD
Re: generator issues
From what you describe, it seems to confirm that the generator is working. I would go with a new regulator. Review the comments on regulators in this forum. Members have had different degrees of success with some of the cheaper foreign units. Compare and price before you buy. Perhaps those who have bought regulators may wish to comment.
-
- Cub Pro
- Posts: 23701
- Joined: Sun Feb 02, 2003 2:09 pm
- Zip Code: 63664
- Tractors Owned: 47, 48, 49 cub plus Wagner loader & other attachments. 41 Farmall H.
- Location: Mo, Potosi
Re: generator issues
This may be a stupid question, but are you sure the battery has not been removed and reinstalled backwards? It is the only thing that really makes since at this point. Buy or borrow a voltmeter and check the voltage, paying attention to polarity. I have seen a generator polarized wrong and charge the battery backward, but it is rare.
If you are not part of the solution,
you are part of the problem!!!
you are part of the problem!!!
-
- 10+ Years
- Posts: 34
- Joined: Mon Jul 23, 2012 7:19 am
- Zip Code: 45862
Re: generator issues
The battery is pos ground, neg hot. I have the wires off the gen., shouldn' I get a reading with the tractor running off the A post on the gen? I will be in and out do to honey-dos. Thanks, Bill
-
- Similar Topics
- Replies
- Views
- Last post
-
- 11
- 458
-
by Dale Finch
Tue Dec 20, 2022 6:48 pm
-
-
Help with a Cub! Fuel issues???? Attachment(s)
by 72chevelle » Tue Mar 08, 2022 12:40 pm » in Farmall Cub - 44
- 1337
-
by Clemsonfor
Wed Mar 16, 2022 8:20 pm
-
-
- 7
- 296
-
by Glen
Wed Sep 21, 2022 6:30 pm
-
- 12
- 379
-
by elongest
Tue Jun 28, 2022 12:31 pm
-
- 6
- 347
-
by Waif
Thu Jun 24, 2021 9:14 am
Who is online
Users browsing this forum: No registered users and 6 guests