I'm having a problem with the battery discharging while the tractor is in use. I have converted a 1953 super A from 6 to 12 volts. I was thinking that instead of charging, that the alternator is discharging the battery while in use. I don't know if that is even possible. Any and all help would greatly be appreciated.
Thanks
DJ
This site uses cookies to maintain login information on FarmallCub.Com. Click the X in the banner upper right corner to close this notice. For more information on our privacy policy, visit this link: Privacy Policy
NEW REGISTERED MEMBERS: Be sure to check your SPAM/JUNK folders for the activation email.
Battery Completly Discharging While Runniong
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
-
- 10+ Years
- Posts: 2
- Joined: Mon Mar 19, 2012 8:28 am
- Zip Code: 19551
-
- Cub Pro
- Posts: 23701
- Joined: Sun Feb 02, 2003 2:09 pm
- Zip Code: 63664
- Tractors Owned: 47, 48, 49 cub plus Wagner loader & other attachments. 41 Farmall H.
- Location: Mo, Potosi
Re: Battery Completly Discharging While Runniong
when you replaced the battery with a 12 volt one did you connect it with the - pole grounded? alternators with rare exceptions are negative ground rather than the positive ground on the original 6 volt systems.What kind of alternator did you use? Many of the one wire alternators have to be revved up quite a bit to get them to charge. If you used one of the 10SI or equivalents it needs to be wired like this.
If you are not part of the solution,
you are part of the problem!!!
you are part of the problem!!!
-
- 10+ Years
- Posts: 2
- Joined: Mon Mar 19, 2012 8:28 am
- Zip Code: 19551
Re: Battery Completly Discharging While Runniong
Thank you John,
I used this exact diagram to wire in the 12 volt system. I do believe the new battery is deffective and is now being replaced, so I will hope for the best.
Thanks Again
DJ
I used this exact diagram to wire in the 12 volt system. I do believe the new battery is deffective and is now being replaced, so I will hope for the best.
Thanks Again
DJ
-
- Similar Topics
- Replies
- Views
- Last post
-
-
Battery for Super A Attachment(s)
by MarkAkerman » Mon May 03, 2021 11:07 am » in Farmall A, Super A, AV, 100, 130 & 140 - 9
- 927
-
by SamsFarm
Thu May 06, 2021 10:49 am
-
-
-
12V battery size for a SAV or SA
by customcutter » Thu Jan 12, 2023 8:57 pm » in Farmall A, Super A, AV, 100, 130 & 140 - 6
- 215
-
by staninlowerAL
Mon Jan 16, 2023 4:24 pm
-
-
-
Battery Box question for 100
by ShawnAgne » Fri Nov 05, 2021 4:43 pm » in Farmall A, Super A, AV, 100, 130 & 140 - 7
- 329
-
by ShawnAgne
Sat Nov 06, 2021 7:51 pm
-
-
-
Super A battery box questions
by 49willard » Mon Jan 16, 2023 1:40 pm » in Farmall A, Super A, AV, 100, 130 & 140 - 9
- 407
-
by ShawnAgne
Tue Jan 24, 2023 9:45 pm
-
-
-
Use of 12 Battery in a 6 Volt System??? Attachment(s)
by BohemianJon » Fri Dec 16, 2022 7:13 am » in Farmall A, Super A, AV, 100, 130 & 140 - 4
- 237
-
by ShawnAgne
Fri Dec 16, 2022 9:01 pm
-
Return to “Farmall A, Super A, AV, 100, 130 & 140”
Who is online
Users browsing this forum: No registered users and 1 guest