This site uses cookies to maintain login information on FarmallCub.Com. Click the X in the banner upper right corner to close this notice. For more information on our privacy policy, visit this link:
Privacy Policy

NEW REGISTERED MEMBERS: Be sure to check your SPAM/JUNK folders for the activation email.

1955 100 Farmall

Farmall Super A, AV, 100, 130, & 140 1939 - 1973
Forum rules
Notice: For sale and wanted posts are not allowed in this forum. Please use our free classifieds or one of our site sponsors for your tractor and parts needs.
Little Red Cub
10+ Years
10+ Years
Posts: 49
Joined: Thu Apr 05, 2007 12:36 pm
Zip Code: 35646
Location: Leighton, Alabama

1955 100 Farmall

Postby Little Red Cub » Wed Mar 16, 2011 5:38 am

Became the proud owner of a 100 Farmall yesterday. It has a one point fast hitch with cultivator, planter, double gang disk,grader blade,bushhog, 2 disk breaker, boom pole, middle buster. It is a 2 owner tractor in pretty good shape.
Now for the problem. The battery was completely dead and after we put a new battery in it the generator would not charge (6 volt) was told it needed to have the generator excited. Can anyone tell me how to do this or if it needs it or do I just need to have the generator rebuilt?
The owner said it was charging when he parked it last fall.

Also need some help on what the equipment might be worth. Will probably sell all but the cultivator and maybe the breaking plow. It was all bought when the tractor was bought new.
Rick
1955 100 Farmall
1998 Kubota L 2900 4 wheel drive with front end loader




Ham and eggs...A day's work for a chicken, a lifetime
commitment for a pig.

SPONSOR AD

Sponsor



Sponsor
 

danovercash
10+ Years
10+ Years
Posts: 3369
Joined: Mon Feb 17, 2003 8:48 pm
Zip Code: 28081
Circle of Safety: Y
Location: NC, Kannapolis

Re: 1955 100 Farmall

Postby danovercash » Wed Mar 16, 2011 6:57 am

Did you install the battery positive ground? (correct way)
Last edited by danovercash on Wed Mar 16, 2011 10:53 am, edited 1 time in total.
"I'd rather be a mechanic in the shop"- Henry Ford

252646 & 221525. 195897 (Gone, but not forgotten)

Little Red Cub
10+ Years
10+ Years
Posts: 49
Joined: Thu Apr 05, 2007 12:36 pm
Zip Code: 35646
Location: Leighton, Alabama

Re: 1955 100 Farmall

Postby Little Red Cub » Wed Mar 16, 2011 7:02 am

Guy I bought it from said to put the hot cable to the ground post on battery and ground cable to hot post. That is the way I hooked it up. Is this right?
Rick
1955 100 Farmall
1998 Kubota L 2900 4 wheel drive with front end loader




Ham and eggs...A day's work for a chicken, a lifetime
commitment for a pig.

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: 1955 100 Farmall

Postby Bigdog » Wed Mar 16, 2011 8:57 am

Positive post on the battery to the ground cable and negative post to the other cable. Touch a jumper wire from the Batt. terminal on the regulator to the Gen terminal on the regulator. That will polarize it.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com

Little Red Cub
10+ Years
10+ Years
Posts: 49
Joined: Thu Apr 05, 2007 12:36 pm
Zip Code: 35646
Location: Leighton, Alabama

Re: 1955 100 Farmall

Postby Little Red Cub » Wed Mar 16, 2011 6:17 pm

Jumped from the batt terminal to the gen terminal but I think it is still discharging. The guage shows discharge but it is very slightly to the discharge side. It has a brand new 6 volt battery. Any other suggestions? Could the guage be wrong? It is just barley off the 0 toward discharge.

When I touched the gen terminal with the jumper I got a pretty good spark.
Rick
1955 100 Farmall
1998 Kubota L 2900 4 wheel drive with front end loader




Ham and eggs...A day's work for a chicken, a lifetime
commitment for a pig.

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: 1955 100 Farmall

Postby Bigdog » Wed Mar 16, 2011 6:21 pm

Take a jumper wire and connect it to the F terminal of the generator and then to ground. If it charges then, your generator is working and the problem is likely with the regulator or connections.
If it does not charge with the generator F terminal grounded the problem is with the generator.
Is your generator belt good and tight?
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com

Little Red Cub
10+ Years
10+ Years
Posts: 49
Joined: Thu Apr 05, 2007 12:36 pm
Zip Code: 35646
Location: Leighton, Alabama

Re: 1955 100 Farmall

Postby Little Red Cub » Wed Mar 16, 2011 7:22 pm

thanks Bigdog I will try that tomorrow. Do I need to ground to the tractor or back to ground on battery
Rick
1955 100 Farmall
1998 Kubota L 2900 4 wheel drive with front end loader




Ham and eggs...A day's work for a chicken, a lifetime
commitment for a pig.

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: 1955 100 Farmall

Postby Bigdog » Wed Mar 16, 2011 8:16 pm

Ground to good clean metal surface on the tractor. Going clear back to the battery isn't necessary but it works too.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com

danovercash
10+ Years
10+ Years
Posts: 3369
Joined: Mon Feb 17, 2003 8:48 pm
Zip Code: 28081
Circle of Safety: Y
Location: NC, Kannapolis

Re: 1955 100 Farmall

Postby danovercash » Thu Mar 17, 2011 5:25 am

Engine RPM's above idle? Generater may not be turning fast enough.
"I'd rather be a mechanic in the shop"- Henry Ford

252646 & 221525. 195897 (Gone, but not forgotten)

Little Red Cub
10+ Years
10+ Years
Posts: 49
Joined: Thu Apr 05, 2007 12:36 pm
Zip Code: 35646
Location: Leighton, Alabama

Re: 1955 100 Farmall

Postby Little Red Cub » Thu Mar 17, 2011 2:49 pm

Took the generator off and carried it and had it checked. It checked good. The wires look good and I tighten the fan belt just in case. They said it was probably the regulator,is there a way to check it?
Rick
1955 100 Farmall
1998 Kubota L 2900 4 wheel drive with front end loader




Ham and eggs...A day's work for a chicken, a lifetime
commitment for a pig.

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: 1955 100 Farmall

Postby Bigdog » Thu Mar 17, 2011 3:24 pm

You can remove the cover and see if the cutout relay is pulling in. You can also check and clean the contacts. Beyond that, everything is pretty much hit and miss unless you have the right tools to do the job.
Did the generator charge with the F terminal grounded? If not, you still have a wiring problem.
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com

Little Red Cub
10+ Years
10+ Years
Posts: 49
Joined: Thu Apr 05, 2007 12:36 pm
Zip Code: 35646
Location: Leighton, Alabama

Re: 1955 100 Farmall

Postby Little Red Cub » Thu Mar 17, 2011 5:39 pm

I couldn't get it to charge by grounding the f terminal. I am getting fire out of the regulator to the generator.
Rick
1955 100 Farmall
1998 Kubota L 2900 4 wheel drive with front end loader




Ham and eggs...A day's work for a chicken, a lifetime
commitment for a pig.

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: 1955 100 Farmall

Postby Bigdog » Thu Mar 17, 2011 7:09 pm

If the generator does not charge with the F terminal grounded but checked OK at the shop I suspect you are not getting a good ground through the generator mounts. Clean up the contacting surfaces on the generator flanges and mounting bracket or run a ground wire from the generator body to a good ground source.

Please explain "I am getting fire out of the regulator to the generator."
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com

Little Red Cub
10+ Years
10+ Years
Posts: 49
Joined: Thu Apr 05, 2007 12:36 pm
Zip Code: 35646
Location: Leighton, Alabama

Re: 1955 100 Farmall

Postby Little Red Cub » Thu Mar 17, 2011 7:39 pm

I accidentally touched the terminal (A terminal think) on the regulator, side with the one wire with a screwdriver and it sparked.
Rick
1955 100 Farmall
1998 Kubota L 2900 4 wheel drive with front end loader




Ham and eggs...A day's work for a chicken, a lifetime
commitment for a pig.

User avatar
Bigdog
Team Cub Mentor
Team Cub Mentor
Posts: 24144
Joined: Sun Feb 02, 2003 12:50 pm
Zip Code: 43113
Circle of Safety: Y
Location: OH, Circleville
Contact:

Re: 1955 100 Farmall

Postby Bigdog » Thu Mar 17, 2011 7:47 pm

Running or not running when this happened?
Bigdog
If you can't fix it with a hammer, you've got an electrical problem.

My wife says I don't listen to her. - - - - - - - - Or something like that!

Image

http://www.cubtug.com


Return to “Farmall A, Super A, AV, 100, 130 & 140”